The Chimney Sweep Online Fireplace, Wood stove, Gas Stove and Barbecue Shop
STOVE DIMENSIONS: 25" WIDE X 25" DEEP (to glass) X 29-11/16" TALL CONNECTOR PIPE USED: 6" SINGLE-WALL OR DOUBLE-WALL STOVEPIPE
HEARTH (FLOOR PROTECTION) REQUIREMENT: ANY 1/4" NON-COMBUSTIBLE MATERIAL
MINIMUM HEARTH EXTENSION FROM SIDES AND REAR OF STOVE: 6"
MINIMUM HEARTH EXTENSION FROM LOADING DOOR OF STOVE: 16"
FLAT WALL INSTALLATIONS:
| CORNER INSTALLATIONS:
|
A: STOVE TO BACKWALL: SINGLE-WALL STOVEPIPE....... 12" DOUBLE-WALL STOVEPIPE........ 5" MANUFACTURED HOUSING*........ 8" ALCOVE*..................... 10" | G: STOVE TO CORNER WALLS:
SINGLE-WALL STOVEPIPE...... 11"
DOUBLE-WALL STOVEPIPE....... 4"
MANUFACTURED HOUSING*....... 8"
|
B: STOVE TO SIDEWALL: SINGLE-WALL STOVEPIPE....... 18" DOUBLE-WALL STOVEPIPE....... 14" MANUFACTURED HOUSING*....... 16" ALCOVE*..................... 16" | H: CENTERLINE PIPE TO CORNER WALLS:
SINGLE-WALL STOVEPIPE...... 25"
DOUBLE-WALL STOVEPIPE...... 18"
MANUFACTURED HOUSING*...... 22"
|
C: CENTERLINE PIPE TO BACKWALL: SINGLE-WALL STOVEPIPE....... 22" DOUBLE-WALL STOVEPIPE....... 15" MANUFACTURED HOUSING*....... 18" ALCOVE*..................... 20" | I: DIAGONAL CORNER TO FRONT OF HEARTH:
SINGLE-WALL STOVEPIPE...... 67"
DOUBLE-WALL STOVEPIPE...... 57"
MANUFACTURED HOUSING*...... 63"
|
D: CENTERLINE PIPE TO SIDEWALL: SINGLE-WALL STOVEPIPE....... 30" DOUBLE-WALL STOVEPIPE....... 26" MANUFACTURED HOUSING*....... 28" ALCOVE*..................... 28" | J: CORNER TO EDGE OF HEARTH:
SINGLE-WALL STOVEPIPE...... 60"
DOUBLE-WALL STOVEPIPE...... 53"
MANUFACTURED HOUSING*...... 67"
|
E: MINIMUM HEARTH WIDTH........ 34" | L: WIDTH OF HEARTH AT FRONT... 36" |
F: BACKWALL TO FRONT OF HEARTH: SINGLE-WALL STOVEPIPE....... 53" DOUBLE-WALL STOVEPIPE....... 46" MANUFACTURED HOUSING*....... 49" ALCOVE*..................... 51" | COMBUSTIBLE ALCOVE DIMENSIONS: MINIMUM 57" Wide X 90" Tall MAXIMUM 48" Deep |
* DOUBLE-WALL PIPE IS REQUIRED FOR ALCOVE AND MANUFACTURED HOUSING INSTALLATIONS
Location of 4" Outside Air Knockout - Top View
|
OUTSIDE AIR SUPPLIED FROM CRAWLSPACEInsert a length of 4" rigid or flexible aluminum intake pipe into the knockout hole in the bottom of the air plenum and extend it down through a 4-1/8" hole in the floor, terminating below the floor insulation. Caulk around the intake pipe and use silicone cement to glue a piece of 1/4" wire rodent mesh to the bottom. | OUTSIDE AIR SUPPLIED THROUGH BACKWALLInsert a length of 4" rigid or flexible aluminum pipe into the knockout hole in the bottom of the air plenum and elbow back through a 4-1/8" hole in the outside wall behind the stove. Attach a 4" dryer vent termination on the outside of the wall, removing the flapper and substituting a piece of 1/4" rodent mesh cemented in place. |