CLEARANCES TO COMBUSTIBLE WALLS

Pacific Energy Vista Classic LE Wood Stove

STOVE DIMENSIONS: 25-3/4" WIDE X 17-3/8" DEEP X 28-3/4" TALL

CONNECTOR PIPE USED: 6" SINGLE-WALL OR DOUBLE-WALL STOVEPIPE

HEARTH (FLOOR PROTECTION) REQUIREMENT: ANY 1/4" NON-COMBUSTIBLE MATERIAL
MINIMUM HEARTH EXTENSION FROM SIDES AND REAR OF STOVE:  4"
MINIMUM HEARTH EXTENSION FROM VIEWING WINDOW OF STOVE: 16"
PE Vista Classic Clearance Diagram
FLAT WALL INSTALLATIONS: 
CORNER INSTALLATIONS: 
A: STOVE TO BACKWALL:
   SINGLE-WALL STOVEPIPE....... 10"
   DOUBLE-WALL STOVEPIPE........ 8"
G: STOVE TO CORNER WALLS:
   SINGLE-WALL STOVEPIPE...... 7"
   DOUBLE-WALL STOVEPIPE...... 5"
  
B: STOVE TO SIDEWALL:
   SINGLE-WALL STOVEPIPE....... 10"
   DOUBLE-WALL STOVEPIPE........ 8"
H: CENTERLINE PIPE TO CORNER WALLS:
   SINGLE-WALL STOVEPIPE.. 19-7/8"
   DOUBLE-WALL STOVEPIPE.. 17-5/8"
  
C: CENTERLINE PIPE TO BACKWALL:
   SINGLE-WALL STOVEPIPE... 17-3/8"
   DOUBLE-WALL STOVEPIPE... 15-3/4"
  
I: DIAGONAL FROM CORNER TO FRONT LOP:
   SINGLE-WALL STOVEPIPE...... 57"
   DOUBLE-WALL STOVEPIPE...... 54"
  
D: CENTERLINE PIPE TO SIDEWALL:
   SINGLE-WALL STOVEPIPE....... 23"
   DOUBLE-WALL STOVEPIPE....... 21"
  
J: CORNER TO EDGE OF HEARTH:
   SINGLE-WALL STOVEPIPE...... 53"
   DOUBLE-WALL STOVEPIPE...... 50"
  
E: MINIMUM HEARTH WIDTH.... 33-3/8" 
L: WIDTH OF FRONT LOP......... 35" 
F: BACKWALL TO FRONT OF HEARTH:
   SINGLE-WALL STOVEPIPE... 43-1/2"
   DOUBLE-WALL STOVEPIPE... 41-1/2"
  

COMBUSTIBLE ALCOVE DIMENSIONS:  
MINIMUM 48" Wide X 84" Tall
MAXIMUM 36" Deep 


Setting up the Vista Classic LE to burn air from outside the house

OUTSIDE AIR SUPPLIED FROM VENTILATED CRAWLSPACE
PE Vista Classic Outside Air through Floor Diagram
Insert a length of 4" rigid or flexible aluminum intake pipe into the knockout hole in the bottom of the air plenum and extend it down through a 4-1/8" hole in the floor, terminating below the floor joists and insulation. Caulk around the intake pipe where it penetrates the floor and use silicone cement to glue a piece of 1/4" wire rodent mesh to the bottom.
OUTSIDE AIR SUPPLIED THROUGH BACKWALL
PE Vista Classic Outside Air through Backwall Diagram
Insert a length of 4" rigid or flexible aluminum intake pipe into the knockout hole in the rear of the air plenum and run back through a 4-1/8" hole in the outside wall behind the stove. Attach a standard 4" dryer vent termination on the outside of the wall, removing the flapper plate and substituting a piece of 1/4" rodent mesh silicone-cemented in place.

Install Manual Button
Click to View or Download the installation manual in .pdf format

Click to return to our Pacific Energy Vista Classic LE Wood Stove page. For other options, click a button below.

link to our Wood Stoves page   link to our Pacific Energy products page   link to our home page

The Chimney Sweep, Inc.
913 Harris Avenue
Bellingham, WA 98225-7032
1(888)-354-6722 toll-free in U.S. & Canada
1(360)-676-9080 FAX
http://www.chimneysweeponline.com

To send us E-Mail, Click Standard E-Mail Window or Contact Us Button (our reply form)
Copyright © 1996 - 2019 The Chimney Sweep, Inc.