The Chimney Sweep Online Fireplace, Woodstove, Gas Stove and Barbecue Shop
STOVE DIMENSIONS: 25-3/4" WIDE X 17-3/8" DEEP X 28-3/4" TALL CONNECTOR PIPE USED: 6" SINGLE-WALL OR DOUBLE-WALL STOVEPIPE HEARTH (FLOOR PROTECTION) REQUIREMENT: ANY 1/4" NON-COMBUSTIBLE MATERIAL MINIMUM HEARTH EXTENSION FROM SIDES AND REAR OF STOVE: 4" MINIMUM HEARTH EXTENSION FROM VIEWING WINDOW OF STOVE: 16"
FLAT WALL INSTALLATIONS:
| CORNER INSTALLATIONS:
|
A: STOVE TO BACKWALL: SINGLE-WALL STOVEPIPE....... 10" DOUBLE-WALL STOVEPIPE........ 8" | G: STOVE TO CORNER WALLS: SINGLE-WALL STOVEPIPE...... 7" DOUBLE-WALL STOVEPIPE...... 5" |
B: STOVE TO SIDEWALL: SINGLE-WALL STOVEPIPE....... 10" DOUBLE-WALL STOVEPIPE........ 8" | H: CENTERLINE PIPE TO CORNER WALLS: SINGLE-WALL STOVEPIPE.. 19-7/8" DOUBLE-WALL STOVEPIPE.. 17-5/8" |
C: CENTERLINE PIPE TO BACKWALL: SINGLE-WALL STOVEPIPE... 17-3/8" DOUBLE-WALL STOVEPIPE... 15-3/4" | I: DIAGONAL FROM CORNER TO FRONT LOP: SINGLE-WALL STOVEPIPE...... 57" DOUBLE-WALL STOVEPIPE...... 54" |
D: CENTERLINE PIPE TO SIDEWALL: SINGLE-WALL STOVEPIPE....... 23" DOUBLE-WALL STOVEPIPE....... 21" | J: CORNER TO EDGE OF HEARTH: SINGLE-WALL STOVEPIPE...... 53" DOUBLE-WALL STOVEPIPE...... 50" |
E: MINIMUM HEARTH WIDTH.... 33-3/8" | L: WIDTH OF FRONT LOP......... 35" |
F: BACKWALL TO FRONT OF HEARTH: SINGLE-WALL STOVEPIPE... 43-1/2" DOUBLE-WALL STOVEPIPE... 41-1/2" | COMBUSTIBLE ALCOVE DIMENSIONS: MINIMUM 48" Wide X 84" Tall MAXIMUM 36" Deep |
OUTSIDE AIR SUPPLIED FROM VENTILATED CRAWLSPACEInsert a length of 4" rigid or flexible aluminum intake pipe into the knockout hole in the bottom of the air plenum and extend it down through a 4-1/8" hole in the floor, terminating below the floor joists and insulation. Caulk around the intake pipe where it penetrates the floor and use silicone cement to glue a piece of 1/4" wire rodent mesh to the bottom. | OUTSIDE AIR SUPPLIED THROUGH BACKWALLInsert a length of 4" rigid or flexible aluminum intake pipe into the knockout hole in the rear of the air plenum and run back through a 4-1/8" hole in the outside wall behind the stove. Attach a standard 4" dryer vent termination on the outside of the wall, removing the flapper plate and substituting a piece of 1/4" rodent mesh silicone-cemented in place. |