The Chimney Sweep Online Fireplace, Woodstove, Gas Stove and Barbecue Shop
STOVE DIMENSIONS: 27-1/8" WIDE X 17 7/16" DEEP X 36" TALL
CONNECTOR PIPE USED: 6" SINGLE-WALL OR DOUBLE-WALL STOVEPIPE
NON-COMBUSTIBLE 1/4" THICK HEARTH (FLOOR PROTECTION) REQUIRED
MINIMUM HEARTH EXTENSION FROM BACKPLATE OF STOVE: 0"
MINIMUM HEARTH EXTENSION FROM SIDES OF STOVE: 3-1/8"
MINIMUM HEARTH EXTENSION IN FRONT OF STOVE DOOR: 16"
FLAT WALL INSTALLATIONS:
| CORNER INSTALLATIONS:
|
A: STOVE TO BACKWALL: SINGLE-WALL STOVEPIPE....... 12" DOUBLE-WALL STOVEPIPE........ 5" MOBILE HOME.................. 5" | G: STOVE TO CORNER WALLS: SINGLE-WALL STOVEPIPE....... 8" DOUBLE-WALL STOVEPIPE....... 3" MOBILE HOME................. 3" |
B: STOVE TO SIDEWALL: SINGLE-WALL STOVEPIPE....... 12" DOUBLE-WALL STOVEPIPE........ 8" MOBILE HOME.................. 8" | H: CENTERLINE PIPE TO CORNER WALLS: SINGLE-WALL STOVEPIPE...... 20" DOUBLE-WALL STOVEPIPE...... 15" MOBILE HOME................ 15" |
C: CENTERLINE PIPE TO BACKWALL: SINGLE-WALL STOVEPIPE....... 18" DOUBLE-WALL STOVEPIPE....... 11" MOBILE HOME................. 11" | I: DIAGONAL FROM CORNER TO FRONT LOP: SINGLE-WALL STOVEPIPE... 58-1/2" DOUBLE-WALL STOVEPIPE... 51-1/4" MOBILE HOME............. 51-1/4" |
D: CENTERLINE PIPE TO SIDEWALL: SINGLE-WALL STOVEPIPE... 25-1/2" DOUBLE-WALL STOVEPIPE... 21-1/2" MOBILE HOME............. 21-1/2" | J: CORNER TO EDGE OF HEARTH: SINGLE-WALL STOVEPIPE... 53-1/2" DOUBLE-WALL STOVEPIPE... 48-1/3" MOBILE HOME............. 48-1/3" |
E: MINIMUM HEARTH WIDTH.... 33-3/8" | L: WIDTH OF FRONT LOP...... 33-3/8" |
F: BACKWALL TO FRONT OF HEARTH: SINGLE-WALL STOVEPIPE... 45-1/2" DOUBLE-WALL STOVEPIPE... 38-1/2" MOBILE HOME............. 38-1/2" | COMBUSTIBLE ALCOVE DIMENSIONS: MINIMUM 43-1/8" Wide X 84" Tall MAXIMUM 36" Deep |
OUTSIDE AIR SUPPLIED FROM VENTILATED CRAWLSPACELocate the 4" round air intake knockout plate at the extreme rear of the underside of the ash box enclosure, just inside the right leg. Insert a length of 4" rigid or flexible aluminum intake pipe which extends down through a 4-1/8" hole in the floor, terminating below the floor joists and insulation. Caulk around the intake pipe where it penetrates the floor and silicone cement a piece of 1/4" wire rodent mesh to the bottom. | OUTSIDE AIR SUPPLIED THROUGH BACKWALLLocate the 4" round air intake knockout plate at the extreme rear of the underside of the ash box enclosure, just inside the right leg. Insert a length of 4" rigid or flexible aluminum intake pipe and elbow back through a 4-1/8" hole in the outside wall behind the stove. Attach a standard 4" dryer vent termination on the outside of the wall, removing the flapper plate and substituting a piece of 1/4" rodent mesh silicone-cemented in place. |