FLAT WALL INSTALLATIONS:
| CORNER INSTALLATIONS:
|
A: STOVE TO BACKWALL:
SINGLE-WALL STOVEPIPE.... 12"
DOUBLE-WALL STOVEPIPE..... 5"
MOBILE HOME*.............. 8"
ALCOVE*.................. 10"
| G: STOVE TO CORNER WALLS:
SINGLE-WALL STOVEPIPE... 11"
DOUBLE-WALL STOVEPIPE.... 4"
MOBILE HOME*............. 8"
|
B: STOVE TO SIDEWALL:
SINGLE-WALL STOVEPIPE.... 18"
DOUBLE-WALL STOVEPIPE.... 14"
MOBILE HOME*............. 16"
ALCOVE*.................. 16"
| H: CENTERLINE PIPE TO CORNER WALLS:
SINGLE-WALL STOVEPIPE... 25"
DOUBLE-WALL STOVEPIPE... 18"
MOBILE HOME*............ 22"
|
C: CENTERLINE PIPE TO BACKWALL:
SINGLE-WALL STOVEPIPE.... 22"
DOUBLE-WALL STOVEPIPE.... 15"
MOBILE HOME*............. 18"
ALCOVE*.................. 20"
| I: DIAGONAL CORNER TO FRONT OF HEARTH:
SINGLE-WALL STOVEPIPE... 67"
DOUBLE-WALL STOVEPIPE... 57"
MOBILE HOME*............ 63"
|
D: CENTERLINE PIPE TO SIDEWALL:
SINGLE-WALL STOVEPIPE.... 30"
DOUBLE-WALL STOVEPIPE.... 26"
MOBILE HOME*............. 28"
ALCOVE*.................. 28"
| J: CORNER TO EDGE OF HEARTH:
SINGLE-WALL STOVEPIPE... 60"
DOUBLE-WALL STOVEPIPE... 53"
MOBILE HOME*............ 57"
|
E: MINIMUM HEARTH WIDTH..... 34"
| L: WIDTH OF HEARTH FRONT... 34"
|
F: BACKWALL TO FRONT OF HEARTH:
SINGLE-WALL STOVEPIPE... 53"
DOUBLE-WALL STOVEPIPE... 46"
MOBILE HOME*............ 49"
ALCOVE*................. 51"
|
COMBUSTIBLE ALCOVE DIMENSIONS:
MINIMUM 56" Wide
MINIMUM 90" Tall
MAXIMUM 48" Deep
|