STOVE DIMENSIONS: 29-13/16" TALL, 29 1/4" WIDE, 25" DEEP (to viewing window) CONNECTOR PIPE USED: 6" SINGLE-WALL OR DOUBLE-WALL STOVEPIPE HEARTH (FLOOR PROTECTION) REQUIREMENT: ANY 1/4" NON-COMBUSTIBLE MATERIAL MINIMUM HEARTH EXTENSION FROM REAR OF STOVE: 0" MINIMUM HEARTH EXTENSION FROM SIDES OF STOVE: 6" MINIMUM HEARTH EXTENSION FROM VIEWING WINDOW:16"
FLAT WALL INSTALLATIONS: | Series LE | CORNER INSTALLATIONS: | Series LE | |
A: STOVE TO BACKWALL: SINGLE-WALL STOVEPIPE DOUBLE-WALL STOVEPIPE |
9" 7-1/2" | G: STOVE TO CORNER WALLS: SINGLE-WALL STOVEPIPE DOUBLE-WALL STOVEPIPE |
6" 5" | |
B: STOVE TO SIDEWALL: SINGLE-WALL STOVEPIPE DOUBLE-WALL STOVEPIPE |
14" 13" |
H: CENTERLINE PIPE TO CORNER
WALLS: SINGLE-WALL STOVEPIPE DOUBLE-WALL STOVEPIPE |
20-1/8" 19-1/8" | |
C: CENTERLINE PIPE TO BACKWALL: SINGLE-WALL STOVEPIPE DOUBLE-WALL STOVEPIPE |
17-5/8" 16-1/8" |
I: DIAGONAL, CORNER TO FRONT EDGE: SINGLE-WALL STOVEPIPE. DOUBLE-WALL STOVEPIPE |
61-3/4" 60-1/3" | |
D: CENTERLINE PIPE TO SIDEWALL: SINGLE-WALL STOVEPIPE DOUBLE-WALL STOVEPIPE |
28-3/4" 27-5/8" |
J: CORNER TO EDGE OF HEARTH: SINGLE-WALL STOVEPIPE DOUBLE-WALL STOVEPIPE |
56-3/4 55-3/4 | |
E: MINIMUM HEARTH WIDTH: | 39" | L: HEARTH WIDTH AT 16" FROM DOOR: | 39" | |
F: BACKWALL TO FRONT OF HEARTH: SINGLE-WALL STOVEPIPE DOUBLE-WALL STOVEPIPE |
49-1/2" 48" |
COMBUSTIBLE ALCOVE DIMENSIONS: MINIMUM MINIMUM MAXIMUM |
61-1/4" Wide 84" Tall 36" Deep |
OUTSIDE AIR SUPPLIED FROM VENTILATED CRAWLSPACEInsert a length of 4" rigid or flexible aluminum intake pipe into the knockout hole in the bottom of the air plenum and extend it down through a 4-1/8" hole in the floor, terminating below the floor insulation. Caulk around the intake pipe and use silicone cement to glue a piece of 1/4" wire rodent mesh to the bottom. | OUTSIDE AIR SUPPLIED THROUGH BACKWALLInsert a length of 4" rigid or flexible aluminum pipe into the knockout hole in the bottom of the air plenum and elbow back through a 4-1/8" hole in the outside wall behind the stove. Attach a 4" dryer vent termination on the outside of the wall, removing the flapper and substituting a piece of 1/4" rodent mesh cemented in place. |
Click to View or Download the installation manual in .pdf format