The Chimney Sweep Online Fireplace, Woodstove, Gas Stove and Barbecue Shop
STOVE DIMENSIONS: 27" WIDE X 24" DEEP X 28" TALL CONNECTOR PIPE USED: 6" SINGLE-WALL OR DOUBLE-WALL STOVEPIPE
HEARTH (FLOOR PROTECTION) REQUIREMENTS:
MATERIAL: ANY SOLID, CONTINUOUS, NON-COMBUSTIBLE MATERIAL
MINIMUM HEARTH EXTENSION FROM SIDES AND REAR OF STOVE... 6"
MINIMUM HEARTH EXTENSION FROM LOADING DOOR OF STOVE.... 16"
FLAT WALL INSTALLATIONS:
| CORNER INSTALLATIONS:
|
A: STOVE TO BACKWALL:
SINGLE-WALL STOVEPIPE....... 19"
DOUBLE-WALL STOVEPIPE
AND REAR HEAT SHIELD......... 8"
| G: STOVE TO CORNER WALLS:
SINGLE-WALL STOVEPIPE....... 14"
DOUBLE-WALL STOVEPIPE
AND REAR HEAT SHIELD........ 14"
|
B: STOVE TO SIDEWALL:
SINGLE-WALL STOVEPIPE....... 18"
DOUBLE-WALL STOVEPIPE
AND REAR HEAT SHIELD........ 18"
| H: CENTERLINE PIPE TO CORNER WALLS:
SINGLE-WALL STOVEPIPE... 27-3/4"
DOUBLE-WALL STOVEPIPE
AND REAR HEAT SHIELD.... 27-3/4"
|
C: CENTERLINE PIPE TO BACKWALL:
SINGLE-WALL STOVEPIPE....... 24"
DOUBLE-WALL STOVEPIPE
AND REAR HEAT SHIELD........ 13"
| I: DIAGONAL CORNER TO FRONT OF HEARTH:
SINGLE-WALL STOVEPIPE....... 73"
DOUBLE-WALL STOVEPIPE
AND REAR HEAT SHIELD........ 73"
|
D: CENTERLINE PIPE TO SIDEWALL:
SINGLE-WALL STOVEPIPE... 31-1/2"
DOUBLE-WALL STOVEPIPE
AND REAR HEAT SHIELD.... 31-1/2"
| J: CORNER TO EDGE OF HEARTH:
SINGLE-WALL STOVEPIPE....... 66"
DOUBLE-WALL STOVEPIPE
AND REAR HEAT SHIELD........ 66"
|
E: MINIMUM HEARTH WIDTH........ 39" | L: WIDTH OF HEARTH AT FRONT.... 39" |
F: BACKWALL TO FRONT OF HEARTH:
SINGLE-WALL STOVEPIPE....... 59"
DOUBLE-WALL STOVEPIPE
AND REAR HEAT SHIELD........ 48"
|
COMBUSTIBLE ALCOVE DIMENSIONS:
MINIMUM 77"WIDE X 75"TALL, MAXIMUM 26"DEEP
(DOUBLE-WALL STOVEPIPE AND REAR HEAT
SHIELD REQUIRED FOR ALCOVE INSTALLATIONS)
|
OUTSIDE AIR SUPPLIED FROM VENTILATED CRAWLSPACEBolt optional outside air adapter to Mansfield at bottom rear. Attach a length of 3" rigid or flexible aluminum pipe to the intake collar with a 3" pipe clamp, then elbow down through a 3-1/8" hole in the floor behind the stove, extending the pipe below the floor joists and insulation. Caulk around the pipe where it penetrates the floor and use silicone cement to glue on a piece of 1/4" wire rodent mesh at the bottom. | OUTSIDE AIR SUPPLIED THROUGH BACKWALLBolt optional outside air adapter to Mansfield at bottom rear. Attach a length of 3" rigid or flexible aluminum intake pipe to the intake collar with a 3" pipe clamp, extend through a 3-1/8" hole in the outside wall behind the stove. Attach a standard 3" dryer vent termination on the outside of the wall, removing the flapper plate and substituting a piece of 1/4" rodent mesh silicone-cemented in place. |