FLAT WALL INSTALLATIONS:
| CORNER INSTALLATIONS:
|
A: STOVE TO BACKWALL:
SINGLE-WALL STOVEPIPE....... 19"
DOUBLE-WALL STOVEPIPE
AND REAR HEAT SHIELD......... 8"
| G: STOVE TO CORNER WALLS:
SINGLE-WALL STOVEPIPE....... 14"
DOUBLE-WALL STOVEPIPE
AND REAR HEAT SHIELD........ 14"
|
B: STOVE TO SIDEWALL:
SINGLE-WALL STOVEPIPE....... 18"
DOUBLE-WALL STOVEPIPE
AND REAR HEAT SHIELD........ 18"
| H: CENTERLINE PIPE TO CORNER WALLS:
SINGLE-WALL STOVEPIPE... 27-3/4"
DOUBLE-WALL STOVEPIPE
AND REAR HEAT SHIELD.... 27-3/4"
|
C: CENTERLINE PIPE TO BACKWALL:
SINGLE-WALL STOVEPIPE....... 24"
DOUBLE-WALL STOVEPIPE
AND REAR HEAT SHIELD........ 13"
| I: DIAGONAL CORNER TO FRONT OF HEARTH:
SINGLE-WALL STOVEPIPE....... 73"
DOUBLE-WALL STOVEPIPE
AND REAR HEAT SHIELD........ 73"
|
D: CENTERLINE PIPE TO SIDEWALL:
SINGLE-WALL STOVEPIPE... 31-1/2"
DOUBLE-WALL STOVEPIPE
AND REAR HEAT SHIELD.... 31-1/2"
| J: CORNER TO EDGE OF HEARTH:
SINGLE-WALL STOVEPIPE....... 66"
DOUBLE-WALL STOVEPIPE
AND REAR HEAT SHIELD........ 66"
|
E: MINIMUM HEARTH WIDTH........ 39"
| L: WIDTH OF HEARTH AT FRONT.... 39"
|
F: BACKWALL TO FRONT OF HEARTH:
SINGLE-WALL STOVEPIPE....... 59"
DOUBLE-WALL STOVEPIPE
AND REAR HEAT SHIELD........ 48"
|
COMBUSTIBLE ALCOVE DIMENSIONS:
MINIMUM 77"WIDE X 75"TALL, MAXIMUM 26"DEEP
(DOUBLE-WALL STOVEPIPE AND REAR HEAT
SHIELD REQUIRED FOR ALCOVE INSTALLATIONS)
|