Our logo
The Chimney Sweep
Online Fireplace, Woodstove, Gas Stove and Barbecue Shop

CLEARANCES & HEARTH REQUIREMENTS

Hearthstone Manchester 8361 Wood Stove

STOVE DIMENSIONS: 30-1/4" WIDE X 20" DEEP X 32-1/4" TALL

CONNECTOR PIPE USED: 6" SINGLE-WALL OR DOUBLE-WALL STOVEPIPE

MINIMUM HEARTH (FLOOR PROTECTION) REQUIREMENTS:
ANY SOLID, NON-COMBUSTIBLE MATERIAL AT LEAST 1/4" THICK
MINIMUM HEARTH EXTENSION FROM BACK PLATE OF STOVE............ 1"
MINIMUM HEARTH EXTENSION FROM SIDE LOADING DOOR OF STOVE.... 16"
MINIMUM HEARTH EXTENSION FROM NON-DOOOR SIDE OF STOVE........ 2"
MINIMUM HEARTH EXTENSION FROM FRONT LOADING DOOR OF STOVE... 16"
Hearthstone Manchester Top Vented Clearance Diagram Hearthstone Manchester Rear Vented Clearance Diagram Hearthstone Manchester Corner Clearance Diagram Manchester Fireplace Installation Diagram
FLAT WALL INSTALLATIONS:
TOP VENTED STOVES
FLAT WALL INSTALLATIONS
REAR VENTED STOVES
CORNER INSTALLATIONS:
TOP/REAR VENTED STOVES
FIREPLACE HEARTH INSTALLATIONS
REAR VENTED STOVES
A: STOVE TO BACKWALL:
WITHOUT REAR HEAT SHIELD.............................. 16"
REAR HEAT SHIELD, SINGLE-WALL STOVEPIPE.... 10"
REAR HEAT SHIELD, DOUBLE-WALL STOVEPIPE... 6"
A: STOVE TO BACKWALL:
SINGLE-WALL STOVEPIPE.... 14"
DOUBLE-WALL STOVEPIPE... 6"
G: STOVE TO CORNER WALLS:
SINGLE-WALL STOVEPIPE...... 9"
DOUBLE-WALL STOVEPIPE.... 9"
M: HEARTH TO OVERHEAD COMBUSTIBLES:
TRIM (UP TO 1" DEEP)..... 38-1/2"
MANTEL (1" - 8" DEEP).... 77-1/2"
B: STOVE TO SIDEWALL (DOOR & SOLID SIDES):
SINGLE-WALL STOVEPIPE..... 18"
DOUBLE-WALL STOVEPIPE... 16"
B: STOVE TO SIDEWALL (DOOR & SOLID SIDES):
SINGLE-WALL STOVEPIPE..... 18"
DOUBLE-WALL STOVEPIPE... 16"
H: CENTERLINE PIPE TO CORNER WALLS:
SINGLE-WALL STOVEPIPE........ 23-1/4"
DOUBLE-WALL STOVEPIPE
...... 23-1/4"
N: MINIMUM HEARTH DEPTH, MEASURED
FROM FIREPLACE FACIA... 36"
C: CENTER OF PIPE TO BACKWALL:
WITHOUT REAR HEAT SHIELD: 21"
REAR HEAT SHIELD, SINGLE WALL STOVEPIPE..... 15"
REAR HEAT SHIELD, DOUBLE-WALL STOVEPIPE... 11"
C: CENTER OF PIPE TO BACKWALL:
SINGLE-WALL STOVEPIPE..... N/A
DOUBLE-WALL STOVEPIPE... N/A
I: CORNER TO FRONT OF HEARTH:
SINGLE-WALL STOVEPIPE..... 64"
DOUBLE-WALL STOVEPIPE... 64"
O: LINER SIZE REQUIRED.... 6"

P: MINIMUM OPENING HEIGHT.... 28-3/4"
D: CENTER OF PIPE TO SIDEWALL:
SINGLE-WALL STOVEPIPE.....33-1/8"
DOUBLE-WALL STOVEPIPE... 31-1/8"
D: CENTER OF PIPE TO SIDEWALL:
SINGLE-WALL STOVEPIPE..... 33-1/8"
DOUBLE-WALL STOVEPIPE... 31-1/8"
J: CORNER TO EDGE OF HEARTH AT WALL:
SINGLE-WALL STOVEPIPE..... 58"
DOUBLE-WALL STOVEPIPE.... 58"
 
E: MINIMUM HEARTH WIDTH:
W/16" ON DOOR SIDE, 2" ON NON-DOOR SIDE... 48"
W/16" ON BOTH SIDES (STOVE CENTERED)...... 62"
E: MINIMUM HEARTH WIDTH:
W/16" ON DOOR SIDE, 2" ON NON-DOOR SIDE... 48"
W/16" ON BOTH SIDES (STOVE CENTERED)..... 62"
L: WIDTH OF HEARTH AT FRONT... 34"  
COMBUSTIBLE ALCOVE DIMENSIONS
MINIMUM 62-1/4" WIDE
MINIMUM 68" TALL W/ SINGLE WALL PIPE
MINIMUM 64" TALL W/ DOUBLE WALL PIPE
MAXIMUM 52" DEEP
F: BACKWALL TO FRONT OF HEARTH:
WITHOUT REAR HEAT SHIELD............................... 52"
REAR HEAT SHIELD, SINGLE-WALL STOVEPIPE..... 46"
REAR HEAT SHIELD, DOUBLE-WALL STOVEPIPE... 42"
F: BACKWALL TO FRONT OF HEARTH:
SINGLE-WALL STOVEPIPE..... 50"
DOUBLE-WALL STOVEPIPE... 42"
 
     

Setting up the Manchester to burn air from outside the house

OUTSIDE AIR SUPPLIED FROM VENTILATED CRAWLSPACE
Outside Combustion Air through Floor diagram
Bolt optional outside air adapter to Manchester at bottom rear. Attach a length of 3" rigid or flexible aluminum pipe to the intake collar with a 3" pipe clamp, then elbow down through a 3-1/8" hole in the floor behind the stove, extending the pipe below the floor joists and insulation. Caulk around the pipe where it penetrates the floor and use silicone cement to glue on a piece of 1/4" wire rodent mesh at the bottom.
OUTSIDE AIR SUPPLIED THROUGH BACKWALL
Outside Combustion Air through Backwall diagram
Bolt optional outside air adapter to Manchester at bottom rear. Attach a length of 3" rigid or flexible aluminum intake pipe to the intake collar with a 3" pipe clamp, extend through a 3-1/8" hole in the outside wall behind the stove. Attach a standard 3" dryer vent termination on the outside of the wall, removing the flapper plate and substituting a piece of 1/4" rodent mesh silicone-cemented in place.

Install Manual Button
Click the Book to view the Manchester manual in .pdf format

Click to return to our Hearthstone Manchester Wood Stove page. For other options, click a button below.

Wood Stoves Button   Hearthstone Logo Button   Home Button 

The Chimney Sweep, Inc.
913 Harris Avenue
Bellingham, WA 98225-7032
1(888)-354-6722 toll-free in U.S. & Canada
1(360)-676-9080 FAX
http://www.chimneysweeponline.com

To send us E-Mail, Click Standard E-Mail Window or Contact Us Button (our reply form)
Copyright © 1996 - 2019 The Chimney Sweep, Inc.